SELECT Head for the CyBio FeliX
Automation just got faster
Automate faster with the SELECT Head pipetting module for CyBio FeliX
The SELECT Head revolutionises liquid handling with 8 independent channels and volumes. Simplify complex transfers by executing directly from your CSV files, liberating you from complicated programming. Avoid slow pipetting bottlenecks in your workflows and automate faster than with a single tip.
Save on space with lightweight automation. With a tiny footprint (65 x 45 cm), the CyBio FeliX and SELECT Head provides a small but powerful solution to complex liquid handling.
With the SELECT Head, make these tedious processes 8 times faster compared to using a single tip:
- Hit Picking
- Normalisation
- Pooling
What is the key to the SELECT Head’s speed?
With fully independent channels, the SELECT Head can process 8 different wells with only one tip change. Cutting down on repetitive movements by up to 8 times. Additionally, each SELECT Head channel has complete volume independence, meaning 8 different volumes can be aspirated in one quick transfer.
Pick up to 8 hits, normalise 8 samples, or pool multiple reagents in one smooth motion, without excess tip changes.
Hit Picking Faster
Pick any 8 wells, simultaneously, across 96, 384 and 1536 formats. Cut down on repetitive movements so you process your picks faster. Easily handle tubes, vials and non-standard labware with 8 independent channel heights. Embrace complete freedom in your well selection by automating with the SELECT Head.
Normalisation Faster
Normalise your samples faster to the correct concentration and volume. The SELECT Head can aspirate 8 different volumes of sample and diluent in the same transfer. Automatically determine the required volumes by reading directly from your input files, instead of calculating them manually.
Pooling Faster
Overhaul slow, single tip pooling in gene assembly and library preparation with the SELECT Head. Accelerate your liquid handling by aspirating up to 8 materials from individual destinations. Automatically transfer to the correct wells specified by your input files, without any additional programming.
Technical Data
With volume ranges from 1000 µL to 1 µL, there is a SELECT Head ready to automate your application. Combine the SELECT Head with any new or existing CyBio FeliX instrument, and get your data faster.
CyBio FeliX Head | SELECT Head 8/1000 µL | SELECT Head 8/250 µL | SELECT Head 8/50 µL |
---|---|---|---|
Order number | OL3318-14 | OL3318-14-420 | OL3318-14-410 |
Plate format | 96, 384 wells and tubes | 96, 384 wells and tubes | 96, 384, 1536 wells and tubes |
Volume range | 10 µL - 1000 µL | 5 µL - 250 µL | 1 µL - 50 µL |
Specified volume range precision | 25 - 100 µL ≤ 2% 100 - 1000 µL ≤ 1% | 10 - 25 µL ≤ 3% 25 - 250 µL ≤ 2% | 3 - 5 µL ≤ 3% 5 - 50 µL ≤ 2% |
Brochures and Flyers
Fyler CyBio FeliX SELECT Head (EN)
Open PDFDemo the SELECT Head Find out how much faster you can automate with the SELECT Head