EA Gas Sampler Series Gain competitve advantage by cost-effective, reliable, highly sensitive gas analysis

  • Extension for wider application spectra at any time
  • Unique flexibility due to variable dosing volumes
  • Convincingly easy and cost-effective calibration strategies
  • Remarkable sensitivity in ultra-trace applications
  • High precision by direct dosing of original samples

Versatile Gas Sampling Systems

  • SilcoNert coating for relevant system components inclusive to prevent sample loss
  • Perma-Purge technology prevents memory effects and sample loss
  • Variable dosing volumes enable apadtation to the sample concentration and cost-effective calibration over a wide concentration range
  • Standard compliant operation – prefabricat library methods
  • Maximum safety – Self Check System, integrated system flow check
  • Easy automated operation via software
  • Integrated particle filter, purge tool, system rinse – effortless operation and maintenance

Download Product Information

The right solution for any sample matrix

GSS/LPG Combi Module

2-in-1 combination of LPG and pressurized gas sampling system. Suitable for liquefied pressurized gases (LPG, LNG, CNG) with pressures up to 18 bar (LPG branch) and pressurized gases up to 200 bar (GSS branch)

  • Free selectable sample volumes up to 50 μL (LPG), up to 20 mL (gas)
  • Two separate sample branches for LPG and GSS to prevent cross contamination
  • High performance technology – automatic flow control, integrated particle filters
  • Cooled sampling valve for LPG dosing – prevents too early evaporation, deflagration and scattering analysis results
  • Loop technology for direct dosing of pressurized gases
  • Multiple dosing to cover wide concentration range
  • Heated evaporation chamber preventing samle loss

GSS Module

Suitable for non-pressurized gases (ambient pressure) and with GSS adapter box for pressurized gases (up to 200 bar)

  • Free selectable sample volumes up to 100 mL, variable in 1 mL steps
  • Maintenance-free, automatic system rinse (prevention of memory effects)
  • SilcoNert™ coating – prevention of adsorption loss
  • Sample supply via gas bags (Tedlar™) or gas bludders
  • Optional GSS adapter box for direct connection of pressurized gas cylinders

LPG 2.0 Module

For direct dosing of liquefied pressurized gases (LPG) with pressures up to 35 bar.

  • Free selectable sample volumes up to 50 μL in 1 µL steps
  • High performance technology: automatic flow control, integrated particle filter
  • Cooled dosing valve – prevents too early evaporation, deflagration and scattering analysis results
  • Multiple dosing to cover wide concentration range and easy calibration
  • Heated evaporation chamber preventing samle loss

Products

Applications

Chemical & Materials

Show applications

Applications

  • Fast and Reliable TS Determination in Liquefied Pressurized Gases (LPG) according to ASTM D6667, ASTM D7551, and DIN EN 17178 (EN)

    Open application

Oil & Gas

Show applications

Applications

  • Fast and Reliable TS Determination in Liquefied Pressurized Gases (LPG) according to ASTM D6667, ASTM D7551, and DIN EN 17178 (EN)

    Open application

Power & Energy

Show applications

Applications

  • Fast and Reliable TS Determination in Liquefied Pressurized Gases (LPG) according to ASTM D6667, ASTM D7551, and DIN EN 17178 (EN)

    Open application

Technical Data

Dimension (width x depth x height)

Gas sampling system - GSS for multi EA 5000 / 5100
450-126.420

300 mm x 500 mm x 470 mm

Gas sampling system for compEAct / multi EA 5010
450-126.410

300 mm x 550 mm x 800 mm

GSS/LPG combi module for multi EA 5000 / 5100
450-126.418

300 mm x 550 mm x 800 mm

GSS/LPG-combi module for compEAct / multi EA 5010
450-126.419

300 mm x 550 mm x 800 mm

LPG module 2.0 for compEAct / multi EA 5010
450-900.466

300 mm x 550 mm x 800 mm

LPG module 2.0 multi EA 5000 / 5100
450-900.465

300 mm x 550 mm x 800 mm

Standards

  • ASTM D3246
  • ASTM D6667
  • ASTM D7551
  • DIN EN 17178
  • UOP 910
  • UOP 988

Order Information

Order number

Description

450-126.420 Gas sampling system - GSS for multi EA 5000 / 5100
450-126.410 Gas sampling system for compEAct / multi EA 5010
450-126.418 GSS/LPG combi module for multi EA 5000 / 5100
450-126.419 GSS/LPG-combi module for compEAct / multi EA 5010
450-900.466 LPG module 2.0 for compEAct / multi EA 5010
450-900.465 LPG module 2.0 multi EA 5000 / 5100

Accessories

Adapterbox for GSS module

Accessory for GSS module enabling analysis of pressurized gases

Order number: 450-007.531

Gas leak detector "sniffer"

Order number: 450-890.032

Extension "sample in" (female)

Accessory for attachment of big sample cylinders

Order number: 450-520.283

Extension "sample in" (male)

Accessory for attachment of big sample cylinders

Order number: 450-520.267

Consumables

Consumables and Spare Parts Kits

Order numberName
450-889.304Consumables & spare parts kit for GSS/LPG combi module

EA Gas Sampler

Order numberName
402-889.180Injection head for GSS, LPG and GSS/LPG, vertical operation
402-889.443Septum perforated for special needle PEEK
402-890.018Special needle for GSS, LPG and GSS/LPG, horizontal operation mode
402-889.147Gas sample bag for non-pressurized gases *
402-889.439Bubble vessel for gas sampling systems
702-520.211Filter element 0.5 µm for line filter assembly (702-520.231) *
402-889.444Particle filter GSS part GSS/LPG combi module

Fittings and Connectors

Order numberName
402-820.057Ferrule 1/16"
402-820.123Ferrule for injection needle, vertical operation

* necessary to operate

Downloads

Brochures & Flyer

User Manuals

TitleLanguageInfo
Operating Manual GSS Modul (DE)GermanPDF, 4 MB
Operating Manual GSS Module (EN)EnglishPDF, 4 MB

Contact us We are happy to help you and will contact you as quickly as possible.