PlasmaQuant MS Series ICP-MS Tailored to Your Requirements

  • Sensitive – 1500 Mcps/ppm at <2 % CeO
  • Cost-effective – half the argon consumption
  • Fast – 50 % higher sample throughput
  • Robust – matrix-independent long-term stability
  • Versatile – optimized for research and routine use

Mass spectrometry with inductively coupled plasma (ICP-MS) is the versatile, sensitive and fast analytical standard method in various fields of application. With the PlasmaQuant MS series, Analytik Jena offers ICP-MS that exceed all expectations in terms of reliability, precision and throughput and fulfill all requirements for sample handling, robustness and compliance.

Sensitivity and Efficiency

The unparalleled level of sensitivity of the PlasmaQuant MS provides you with analytical advantages that are clearly reflected in efficiency and lower costs per sample. The patented spectrometer design of the ICP-MS systems provide for the lowest detection limits and consistent analytical quality for extremely short integration times and high dilution factors. This ensures high throughput, long-term stability, and reproducible results, while significantly reducing your maintenance costs.

  • Best detection limits
  • High throughput
  • Reduced sample preparation
  • Robust performance
  • Low maintenance requirements

Download Product Information

Market Leading Performance and Lowest Running Costs

Analytik Jena's ICP-MS solutions offer market-leading sensitivity. With these powerful and reliable instruments, laboratories can meet the current challenges of increasing sample throughput or reducing measurement times without sacrificing high analytical precision and reproducibility.

Unmatched detection performance

Excellent mass separation and unmatched detection sensitivity (up to 1500 Mcps/ppm at <2 % CeO) for low abundance isotopes enable the detection of extremely low elemental concentrations, low elemental species concentrations and single particles of less than 5 nm in diameter, as well as offering outstanding precision in the determination of isotope ratios.

Highest sample throughput

In many applications, however, speed of analysis is just as important as detection strength and precision. Higher sample throughput significantly reduces the cost per sample. The unmatched high sensitivity of the PlasmaQuant MS and the resulting precision advantage make it possible to achieve the highest sample throughput in the ICP-MS market with up to 80 samples per hour*.

Powerful plasma flame

The ICP-MS instruments offer excellent plasma robustness, which results in high long-term flame stability. This ensures reliable characterization of samples with high matrix loads as well as minimized drift with changing matrix loads.

Outstanding cost efficiency

The German-made ICP-MS systems are also very economical in daily operation. Compared to other instruments on the market, they consume up to 50 % less argon gas, i.e. approximately 10 l/min. They also achieve a reduction of up to 50 % in plasma operating costs.The combination of detection strength, speed, reduced argon consumption and high throughput translates into a significantly lower cost per sample. In addition, the design of the system - be it the patented spectrometer or the open book design of the entire instrument, which ensures easy and independent accessibility - reduces maintenance requirements.

*Analytik Jena AppNote High-throughput Analysis of Drinking Water with ICP-MS

Products

Applications

Chemical & Materials

Show applications

Applications

  • High-precision analysis of glass samples with superior sensitivity using LIBS and LA-ICP-MS (EN)

    Open application

  • Elemental Mapping of Printed Ink Using the J200 Tandem LA-LIBS Instrument in Combination with the PlasmaQuant MS Elite (EN)

    Open application

  • Determination Trace Elements in Toys (EN)

    Open application

  • Achieving Lowest Detection Limits Using the PlasmaQuant MS Elite S (EN)

    Open application

  • Achieving Lowest Detection Limits Using the PlasmaQuant MS Elite S (Japanese)

    Open application

  • Determination of Hexavalent Chromium in Toy Samples According to EN 71-3 (EN)

    Open application

  • Determination of Gold Nanoparticles in Drinking Water by Single Particle ICP-MS (spICP-MS) according with ISO/TS 19590:2016 (EN)

    Open application

Environment

Show applications

Applications

  • Speciation of Arsenic in Apple Juice by LC-ICP-MS on PlasmaQuant MS Elite (EN)

    Open application

  • Monitoring Drinking Water Quality with the PlasmaQuant MS (EN)

    Open application

  • Ultra-Trace Determination of Mercury in Environmental Waters by ICP-MS (EN)

    Open application

  • Determination of Trace Elements in Seawater using ICP-MS (EN)

    Open application

  • Hochdurchsatz-Analyse von Trinkwasser mit ICP-MS (DE)

    Open application

  • High-throughput Analysis of Drinking Water with ICP-MS (EN)

    Open application

  • Analysis of Marine Sediments and Sewage Sludge by PlasmaQuant MS (EN)

    Open application

  • Analysis of Marine Sediments and Sewage Sludge (JP)

    Open application

  • Achieving Lowest Detection Limits Using the PlasmaQuant MS Elite S (EN)

    Open application

  • Achieving Lowest Detection Limits Using the PlasmaQuant MS Elite S (Japanese)

    Open application

  • Bestimmung von Quecksilber im Ultraspurenbereich mit ICP-MS (DE)

    Open application

  • Analyse von Meeressedimenten und Klärschlamm mit dem PlasmaQuant MS

    Open application

  • Bestimmung arbeitsplatzrelevanter Gefahrstoffe in Stäuben nach DIN EN 14385 mittels ICP-MS [DE]

    Open application

  • Measuring Toxic Elements in Workplace Filter Dusts According to EN 14385 Using ICP-MS [EN]

    Open application

  • Determination of Trace Metals in Wastewater with PlasmaQuant MS following US EPA 200.8 Method (EN)

    Open application

  • Determination of Trace Elements in Waste Eluates and Leachates in Accordance with DIN EN ISO 17294-2 Using ICP-MS (EN)

    Open application

  • Bestimmung von Spurenelementen in Eluaten und Sickerwässern gemäß Deponieverordnung nach DIN EN ISO 17294-2 mittels ICP-MS (DE)

    Open application

  • Abwasseranalyse nach US EPA 200.8 mit ICP-MS (DE)

    Open application

  • Arsenic Speciation in Soils and Sediments (EN)

    Open application

  • Multielemental Analysis of Soils using ICP-MS after Microwave-assisted Digestion in Compliance with HJ 766 and ISO 14869 (EN)

    Open application

  • Multielement determination of trace elements in undiluted seawater by ICP-MS (EN)

    Open application

  • Determination of 60 Elements in Geological Samples Using Microwave-assisted Digestion Followed by ICP-MS Analysis (EN)

    Open application

  • ​​Multielementbestimmung nach Ersatzbaustoffverordnung mittels ICP-MS am Beispiel eines Boden-Referenzmaterials​ (DE)

    Open application

Food & Agriculture

Show applications

Applications

Geology, Mining & Metals

Show applications

Applications

  • Analysis of Rare Earth Elements by ICP-OES and ICP-MS − Potentials and Limitations (EN)

    Open application

  • Trace Metals Analysis in High Purity Gold Using PlasmaQuant MS Elite (EN)

    Open application

  • Analysis of Geological Materials for Rare Earth Elements on the PlasmaQuant MS Elite (EN)

    Open application

  • Analysis of Metal Alloys using LA-ICP-MS (EN)

    Open application

  • Analysis-of-Nickel-Metal-Alloys-by-LA-ICP-MS

    Open application

  • Determination of Trace Elements in Copper by ICP-MS (EN)

    Open application

  • Achieving Lowest Detection Limits Using the PlasmaQuant MS Elite S (EN)

    Open application

  • Achieving Lowest Detection Limits Using the PlasmaQuant MS Elite S (Japanese)

    Open application

  • Analysis of Rare Earth Elements by ICP-OES and ICP-MS − Potentials and Limitations (DE)

    Open application

  • Trace Metals Analysis in High Purity Gold Using PlasmaQuant MS Elite (DE)

    Open application

  • Analysis of Geological Materials for Rare Earth Elements on the PlasmaQuant MS Elite (DE)

    Open application

  • Analysis of Metal Alloys using LA-ICP-MS (DE)

    Open application

  • Determination of Trace Elements in Copper by ICP-MS (DE)

    Open application

  • Determination of 60 Elements in Geological Samples Using Microwave-assisted Digestion Followed by ICP-MS Analysis (EN)

    Open application

Oil & Gas

Show applications

Applications

  • Analysis of Elemental Impurities in Naphtha by ICP-MS According to ASTM D8110-17 (EN)

    Open application

  • Bestimmung von Element-Verunreinigungen in Naphtha mittels ICP-MS nach ASTM D8110-17 (DE)

    Open application

Pharma & Life Sciences

Show applications

Applications

  • Analysis of Low Level Beryllium in Urine Using the PlasmaQuant MS (EN)

    Open application

  • Elemental Impurities in Pharmaceutical Materials according to new ICH Guidelines and USP Chapters and (JP)

    Open application

  • Iron Isotope Ratios in Human Whole Blood by ICP-MS (EN)

    Open application

  • Multi-element Analysis of Biological Materials by ICP-MS using Alkali Dilution (EN)

    Open application

  • BOOSTing limits of detection for chromium and other trace elements in whole blood (EN)

    Open application

  • Achieving Lowest Detection Limits Using the PlasmaQuant MS Elite S (EN)

    Open application

  • Achieving Lowest Detection Limits Using the PlasmaQuant MS Elite S (Japanese)

    Open application

  • AppNote_ICP-MS_0031_Metals Content in Eye Drops

    Open application

  • Analysis of Trace Metals in Cannabis and Cannabis Products by ICP-MS (EN)

    Open application

  • Determination of Elemental Impurities in Pharmaceuticals by ICP-MS in accordance with ICH Q3D and USP 232 and 233 using the Example of Folic Acid (EN)

    Open application

  • Determination of Trace Elements in Blood Serum and Plasma Using ICP-MS (EN)

    Open application

  • ​​Bestimmung von Spurenelementen in Blut-Serum und -Plasma mittels ICP-MS unter Verwendung von gebrauchsfertigen IVD-Kits​ (DE)

    Open application

Power & Energy

Show applications

Applications

  • Determination of Trace Elements and Isotope Ratios in Borated Cooling Water of Nuclear Power Plant (EN)

    Open application

Technical Data

Detector

Roughing pump

Collision/reaction gas

Cones/Interface

Resolution

Plasma Gas Flow

Doubly charged ion formation rate

Adaptive mass range (AMR)

Min. dwell time

Quadrupol Scanspeed

Low mass background

Oxide ratio

Sensitivity

Dimension (width x depth x height)

PlasmaQuant MS - high sensitive, robust and reliable ICP-MS Instrument
818-08010-2

Discrete dynode electron multiplier (DDEM), all-digital detector Leybold SV40 Helium / Hydrogen Standard Cones Nickel (Platinum available) 0.5 - 1.2 amu 7.5 - 10.5 L/min Ba++/ Ba+ < 3 % Ce++/ Ce+ < 2 % optional
(for elements > 230 amu resolution > 2 amu)
50 µs 5115 amu/s at 5 amu <0.5 cps CeO+/Ce+ < 2 % 9Be > 20 kcps/ppb
115In > 500 kcps/ppb
208Pb > 225 kcps/ppb
iCRC Mode He: 59Co > 40 kcps/ppb
660 mm x 589 mm x 1131 mm

PlasmaQuant MS Elite - ultimate sensitivity for targeted research applications
818-08021-2

Discrete dynode electron multiplier (DDEM), all-digital detector Edwards XDS 46, oil free Helium / Hydrogen Elite Cones Platinum (Nickel available) 0.5 - 1.2 amu 7.5 - 10.5 L/min Ba++/ Ba+ < 3 % Ce++/ Ce+ < 2 % optional
(for elements > 230 amu resolution > 2 amu)
50 µs 5115 amu/s at 5 amu <1 cps CeO+/Ce+ < 2 % 9Be > 50 kcps/ppb
115In > 1500 kcps/ppb
208Pb > 600 kcps/ppb
iCRC Mode He: 59Co > 50 kcps/ppb
660 mm x 589 mm x 1131 mm

PlasmaQuant MS Elite S - high sensitivity and flexibility for efficient analysis
818-08020-2

Discrete dynode electron multiplier (DDEM), all-digital detector Edwards XDS 46, oil free Helium / Hydrogen Pro Cones Nickel (Pro Cones Platinum available) 0.5 - 1.2 amu 7.5 - 10.5 L/min Ba++/ Ba+ < 3 % Ce++/ Ce+ < 2 % optional
(for elements > 230 amu resolution > 2 amu)
50 µs 5115 amu/s at 5 amu <0.7 cps CeO+/Ce+ < 2 % 9Be > 35 kcps/ppb
115In > 1100 kcps/ppb
208Pb > 450 kcps/ppb
iCRC Mode He: 59Co > 40 kcps/ppb
660 mm x 589 mm x 1131 mm

PlasmaQuant MS Q - for sensitive and robust high throughput analysis
818-08011-2

Discrete dynode electron multiplier (DDEM), all-digital detector Leybold SV40 Helium / Hydrogen Pro Cones Nickel (Pro Cones Platinum available) 0.5 - 1.2 amu 7.5 - 10.5 L/min Ba++/ Ba+ < 3 % Ce++/ Ce+ < 2 % optional
(for elements > 230 amu resolution > 2 amu)
50 µs 5115 amu/s at 5 amu <0.7 cps CeO+/Ce+ < 2 % 9Be > 25 kcps/ppb
115In > 800 kcps/ppb
208Pb > 300 kcps/ppb
iCRC Mode He: 59Co > 40 Mcps/ppm
660 mm x 589 mm x 1131 mm

For more information about our products and possible variants, please refer to the technical documents or use our contact form.

Standards

  • (EU) 2017/746 (IVDR)
  • DIN EN 14385
  • DIN EN ISO 17294 - part 1
  • DIN EN ISO 17294 - part 2
  • EN 16172
  • EN 71-3
  • EPA 200.8
  • Ersatzbaustoffverordnung (EBV)
  • HJ 766
  • ISO 105-E04
  • ISO 14869
  • ISO 16967
  • ISO 16968
  • SEMI C33
  • SEMI F57
  • USP 232
  • USP 233

Order Information

Order number

Description

818-08010-2 PlasmaQuant MS - high sensitive, robust and reliable ICP-MS Instrument
818-08021-2 PlasmaQuant MS Elite - ultimate sensitivity for targeted research applications
818-08020-2 PlasmaQuant MS Elite S - high sensitivity and flexibility for efficient analysis
818-08011-2 PlasmaQuant MS Q - for sensitive and robust high throughput analysis

More customer success stories

Patented Technology and Ingenious Solutions

Uniquely cost-efficient − Eco Plasma

For a wide range of sample matrices from wastewater to organic solvents, the Eco Plasma of the PlasmaQuant MS series offers extremely reliable performance at greatly reduced operating costs. The specially developed plasma system enables ICP-MS operation with less than 9 l/min argon gas with exceptional matrix tolerance, low oxide formation (<2 % CeO+/Ce+), and low formation of doubly charged ions (<3 % Ba++/Ba+). Plasma power from 300 to 1600 W guarantees optimum plasma conditions for every application.

  • Robust plasma power
  • Lowest operating costs

Reliably on the mark – effective elimination of spectral interferences using iCRC

The unique interference management system with the integrated Collision Reaction Cell (iCRC) allows for the fast, simple and effective elimination of spectral interference in ICP-MS analysis by using the collision and reaction gases helium (He) and hydrogen (H2). Both gases can be added depending on the matrix and greatly improve accuracy. The BOOST technology maintains the sensitivity in gas mode, allowing undisturbed analytes to be measured in gas mode without reducing their detection limits.

  • Reliable results through the efficient elimination of spectral interferences
  • High productivity due to the fast switching between gases and BOOST technology
  • Excellent long-term stability for complex matrices

Unparalleled sensitivity and throughput – ReflexION

The market-leading sensitivity provided by the PlasmaQuant MS instruments guarantees the best detection limits and allows for a significant reduction of the measuring time, all without compromising precision and reproducibility. This is achieved by ReflexION, a patented ion optics system with true 90-degree reflection and 3D-controlled focusing of the ion beam. The ReflexION reflects the ion beam by generating a parabolic electrostatic field. Analyte ions of different sizes and energy are focused on the quadrupole. This ensures a maximum signal for all analyte ions across the entire mass range. Photons, neutrals, and particles pass through the electrostatic field and are removed by the vacuum system.

  • High sensitivity due to reflection and focusing of the ion beam on the quadrupole input
  • Simple optimization through complete 3D control of the ion beam
  • Low background as photons and neutral particles are not reflected

Efficient and versatile – HD Quadrupole

The PlasmaQuant MS is able to quantify all known stable isotopes with its mass coverage of 3 to 260 amu. The HD quadrupole system with a true 3 MHz quadrupole provides outstanding mass separation and superior abundance sensitivity of 2.3x10-8 for m-1 238U with a minimum residence time of 50 µs and a scan speed of 5115 amu/sec. It offers optimal performance for isotope analysis as well as for laser ablation and single particle analysis.

  • Powerful isotope analysis due to a market-leading level of mass seperation
  • Detection of particles >10 nm in diameter due to ultra-rapid scanning speeds
  • Best detection limits due to a low background noise of <1 count/sec
  • AMR (adaptive mass range version: for m/z >230 amu resolution >2 amu) for restricted isotope separation optionally available

Flexible and precise – all-digital detection

The AD Detection, all-digital detection, system provides 11 orders of analytical range (0.1–1010 cps) in pulse-counting mode only. This enables a fast and accurate multi-element analysis from ultra-trace to high concentrations in a single measurement and ensures exceptional detector lifetime.

  • True wide-range multi-element analysis – 11 orders of analytical range
  • Fast stand-by readiness for measurement and simple application – no cross-calibration
  • Outstanding detector lifetime

Nitrox: Improved analytical performance in petrochemical applications or for the determination of As and Se

The Nitrox is a fully automatic, mass flow controlled accessory that allows for the online addition of N2 or O2 to the auxiliary plasma gases. Nitrogen is a commonly used gas for improving ICP-MS performance through improved ionization of analytes in plasma, as well as the reduction of polyatomic interferences and matrix effects. The addition of oxygen allows direct analysis of organic solvents, significantly reducing the sample preparation time.

Aerosol Dilution: Efficient analysis of high TDS samples

Aerosol dilution is a simple method of measuring samples with high concentrations of total dissolved solids (TDS) on the ICP-MS without the need for complex sample dilution. Analytik Jena's Aerosol Dilution enables direct analysis of samples with high TDS values, such as seawater.

Accessories

Pump Noise Reduction -Noise prevention enclosure for roughing vacuum pump PQ MS 810-88105-0
Aerosol Dilution Upgrade Kit for PQMS and PQMS Elite instruments 810-88512-0
oneFAST Complete 810-88100-0
PQ LC - HPLC System, stainless steel 810-88403-0
PQ LC - HPLC System, non metal, PEEK 810-88409-0
Trigger-Box TTL 810-88060-0
Starter Kit PQMS STANDARD 810-88518-0
Ultrasonic nebulizer U5000AT+ for ICP-OES and ICP-MS 810-88004-0
Argon humidifier with bypass for PlasmaQuant 9x00 series 810-88033-0
Bench for ICP - heavy duty, long basic 810-88523-0
Bench for ICP - heavy duty, long full config 810-88521-0
Bench for ICP - heavy duty, short 810-88112-0
Bench for ICP/AAS for AAS, ICP-OES and ICP-MS instrumentation 810-88005-0
Cetac ASXPress Plus for PQMS 810-88017-0
Druckminderer für Helium 10-406-165
Druckminderer für Wasserstoff 10-406-166
Exhaust Filter Set for roughing pump PQ MS 810-88104-0
Exhaust hose ICP-MS 810-88110-0
Hydride system HS Pro PQMS 810-88037-0
Hydrogen Generator - Precision hydrogen 200 cc/min (ml/min) 810-88026-0
Kit internal standards (PQ MS) 810-88057-0
Nitrox upgrade Kit for PQMS and PQMS Elite instruments 810-88025-0
PQMS Sample Intro Kit GeoChem - Inert Kit with Sapphire Injector for geochemical Sample Matrix 810-88059-0
PQMS Sample Intro Kit with Platinum Injector for ultratrace 810-88058-0
Starter Kit PQMS INERT Geochem with sapphire injector 810-88510-0
Starter Kit PQMS INERT Semicon Sample Introduction Kit for corrosive sample matrix 810-88511-0
Starter Kit PQMS ORGANIC - for organic solvents and volatile matrices 810-88509-0
Teledyne Cetac SimPrep with ASX-560 Autosampler 810-88019-0
Teledyne-Cetac ASX-560 autosampler for ICP-OES and ICP-MS 810-88015-0
Upgrade Kit PQMS Organic 2 - introduction system for volatile organic samples 810-88055-0
Uprgrade Kit PQMS Organic 1 - introduction system for non-volatile organic samples 810-88056-0
Vorvakuumpumpenschlauch pre-vacuum pump hose, customer-specific length 810-88108-0
Water-air-chiller (Labtech) for ICP-OES and ICP-MS 810-88001-0
Water-Water-Chiller (vdH) for ICP-OES and ICP-MS 810-88036-0

Software

ASpect MS Software

With the intuitive worksheet interface of the ASpect MS software for the ICP mass spectrometers of the PlasmaQuant MS series, you can retrieve all analysis data, mass scan graphs, calibration data, and data logs with a single click of the mouse. Detailed quality assurance protocols guarantee accurate data for reliable analysis. ASpect MS provides compliance support in accordance with 21 CFR Part 11.

 

Simple to operate thanks to intelligent automation options

  • Set-up and initialization processes
  • Plasma alignment
  • Mass calibration and resolution tests
  • AutoMax for simple method development
  • Integrated aerosol dilution for the online dilution of samples with a high TDS content
  • BOOST technology for high sensitivity in gas mode (interference management)
  • FDA 21 CFR Part 11 compliance
Product Required Included
PlasmaQuant MS - high sensitive, robust and reliable ICP-MS Instrument (818-08010-2)
PlasmaQuant MS Elite - ultimate sensitivity for targeted research applications (818-08021-2)
PlasmaQuant MS Elite S - high sensitivity and flexibility for efficient analysis (818-08020-2)
PlasmaQuant MS Q - for sensitive and robust high throughput analysis (818-08011-2)

Consumables

418-88097-0 Set tube connector nebulizer gas for ICP-OES and ICP-MS
418-88012-0 6x Pumpschlauch Si wei?/wei?
418-88022-0 12x Pumpschl TPO or/ge 0,02 ID
418-88024-0 12x Pumpschl TPO w/w 0,04 ID
418-88222-0 12x Pump tubing Viton orange/white (0.025 in. ID)
418-88225-0 Argon gas inline filter
418-88226-0 Sample Rack ICP, 60 positions, 14 ml vials
418-88068-0 ICP-MS Transfer Rohr, Quarz Sheath Gas Transfer Tube with Argon connection, quartz
407-402.926 Polypropylene sample vials 50 mL
810-88049-0 Consumables set organic samples for PlasmaQuant MS all models
418-88076-0 End Cap, Scott Spraychamber
418-88014-0 6x Pumpschlauch Si blau/blau Pump tubing Silicon blue/blue (0.065 in. ID)
418-88020-0 12x Pumpschl Vi bl/bl 0,065 ID Pump tubing Viton blue/blue (0.065 in. ID)
418-88030-0 Pump tubing orange/green (0.38 mm ID) flared ends, FT
407-400.057 Polypropylene sample vials 15 mL
418-88067-0 ICP-MS transfer tube, without sheath gas adapter, quartz
418-88025-0 12x Pumpschl TPO gr/gr 0,05 ID Pump tubing Santoprene grey/grey (0.05 in. ID)
418-88061-0 ICP-MS Torch 0,8mm Injektor ICP-MS Torch 0.8mm Injector, quartz
810-88106-0 Consumables set PQ MS all incl. for PlasmaQuant MS
418-88040-0 Sampler Cone Elite, Nickel
418-88041-0 Sampler Cone Elite, Platinum
418-88010-0 6x Pumpschlauch Si oran/gelb Pump tubing Silicon orange/yellow (0.02 in. ID)
418-88148-0 PFA Tubing Kit for ICP-MS PFA tubing kit for PQMS (Elite)
418-88042-0 Sampler Cone, Nickel
418-88043-0 Sampler Cone, Platinum
899-PC2A2 ICP Standard, Calcium 1,000 mg/L in 2 - 5% HNO3
810-88051-0 Consumables Kit inert/geochem for PlasmaQuant MS all models
810-88107-0 Consumables set Elite all incl. for PlasmaQuant MS Elite
418-88023-0 12x Pumpschl TPO sw/sw 0,03 ID Pump tubing Santoprene black/black (0.03 in. ID)
810-88118-0 Consumables set Elite S all incl. for PQ MS Elite S
810-88117-0 Consumables set Q all incl. for Plasma Quant MS Q
418-88078-0 GazFit Schlauchverb. 6mm ID Connectors for torch gas lines (4 pcs.)
418-88007-0 12x Pumpschlauch sf grau/grau Pump tubing solvent flexible grey/grey (0.05 in. ID)
418-88063-0 ICP-MS Torch Body
418-10-405-586 Tube Nalgene 0.12 IDX0.062INTK Tube Nalgene 0.12 IDX0.062INTK (m)
418-88011-0 6x Pumpschlauch Si schw/schw Pump tubing Silicon black/black (0.03 in. ID)
418-13-410-540 cooling water additives (2 components)
418-88028-0 12x Pumpschl.sw/sw 0,03 ID Pump tubing black/black (0.03 in. ID), flared ends
418-88075-0 Cleaning Powder, 500g
418-88137-0 Sampler Cone PRO, Platin Sampler Cone PRO, Platinum for PQMS Q and PQMS Elite S
418-88008-0 12x Pumpschlauch sf blau/blau Pump tubing solvent flexible blue/blue (0.065 in. ID)
418-10-406-251 Öl für Vorvakuumpumpe SV40 PFP Oil for rotary pump SV40 PFPE, Leybonol LVO 420
418-88136-0 Sampler Cone PRO Nickel for PQMS Q and PQMS Elite S
418-88002-0 12x Pumpschlauch oran/wei? Pump tubing orange/white (0.025 in. ID)
418-88089-0 Vacuum pump oil LVO 200, 1L
810-88050-0 Consumables set volatile org. samples for PlasmaQuant MS all models
418-88105-0 Helix Seal, 4 pcs.
418-88017-0 12x Pumpschlauch Vi schw/schw Pump tubing Viton black/black (0.03 in. ID)
418-88018-0 12x Pumpschlauch Vi wei?/wei? Pump tubing Viton white/white (0.04 in. ID)
418-88004-0 12x Pumpschlauch blau/blau Pump tubing blue/blue (0.065 in. ID)
418-88086-0 Y-connector (1/16 in. ID) ,set of 5 pcs
418-88006-0 12x Pumpschlauch sf schw/schw Pump tubing solvent flexible black/black (0.03 in. ID)
418-88026-0 12x Pumpschl TPO bl/bl 0,065ID Pump tubing Santoprene blue/blue (0.065 in. ID)
418-88013-0 6x Pumpschlauch Si grau/grau Pump tubing Silicon grey/grey (0.05 in. ID)
418-88087-0 Drain tube, Scott spraychamber
418-88062-0 ICP-MS Torch1,5mm Injektor ICP-MS Torch 1.5mm Injector, quartz
418-88019-0 12x Pumpschlauch Vi grau/grau Pump tubing Viton grey/grey (0.05 in. ID)
418-88072-0 ICP-MS Scott-Spraychamber, PFA
418-88029-0 Pump tubing black/black (0.76 mm ID), flared ends, FT
899-ICPT9B ICP-MS Tuning Solution Multi Element, 9 Elements, 10 mg/L in 2% HNO3
418-88031-0 Pump tubing blue/blue (1.65 mm ID), flared ends, FT
418-88147-0 Endcap with Gasport - PFA PureCap for 35 mm spray chamber, including make-up gas
418-88146-0 PFA Microflow nebulizer 20 μL/min
418-88150-0 2-Channel Peristaltic Pump Cartrige Tygon tubing, ID 2.2 mm for ASX 560
418-88239-0 Nebulizer tubing 1/16'' OD with UniFit connector (10x)
418-88240-0 O-Ring Sampler Cone für PlasmaQuant MS (5x)
418-13-410-420 Cleaning tool for concentric nebulizer
899-ICPC18L ICP Calibr Std, 18 elements Multi Element Calibration Standard, 100 mg/L in 2-5%HNO3
899-ICPC23Q ICP Calibr Std, 23 elements Multi Element Calibration Standard, 1,000 mg/L in 6% HNO3
899-ICPC4K ICP Calibr Std, 4 elements Multi Element Calibration Standard, 100 mg/L in 5% HNO3 & 1% HF
899-ICPC5BN ICP Calibr Std, 5 elements Multi Element Calibration Standard, 1 mg/L in 2-5% HNO3
899-ICPC5R ICP Calibr Std, 5 majors Mineral Standard Ca, K, Mg, Na, Fe, 500 mg/L in 2-5% HNO3
899-ICPI6A ICP Internal Standard Solution Multi Element, 6 Elements, 100 mg/L in 2-5% HNO3
418-88071-0 Scott-Spruhkammer, Glas ICP-MS Scott-Spraychamber, glass
418-88065-0 Injector, Sapphire, 1.8mm
418-88066-0 Injektor Platin 2,0mm
418-88079-0 Kit O-Rings for Scott spraychamber
810-88421-0 Maintenance Kit H2 Generator
418-88090-0 Metal clamp for ball joint
418-88069-0 Nebulizer PFA 100uL/min
418-88093-0 Nebulizer Tubing 1.3 mm OD with UniFit connector
418-88049-0 O-Ring Set Skimmer Cone
418-88083-0 Sample inlet tubing
418-88092-0 Seaspray Nebulizer Nebulizer for high salt content, glass, 0.4 mL/min
418-88060-0 Standard ICP-MS Torch 2,4mm injector, quartz
418-88070-0 Standard nebulizer Micromist, glass, 0.4mL/min
418-88088-0 Standard PVC drain tubing from pump to waste
418-88085-0 Tubing connector (1/16 in. ID to 1/16 in. ID)
418-88084-0 Tubing connector (1/16 in. ID to 1/8 in. ID)
418-88082-0 Tube sheath gas
418-88081-0 Tube Plasma- and Auxiliary gas
418-88080-0 Tube nebulizer gas
418-10-405-196 Tube nebulizer gas
418-88101-0 coolant tubing - inlet/outlet of peltier element
418-88139-0 Sheath gas tube PFA
418-88045-0 Skimmer Cone, iCRC, Nickel
418-88046-0 Skimmer Cone, iCRC, Platin
418-88047-0 Skimmer Cone, non-iCRC, Nickel
418-88048-0 Skimmer Cone (Platin) Skimmer Cone, non-iCRC, Platinum
418-10-405-940 Torch adapter 12/5 glass
418-88102-0 Tubing set for PQ MS
418-88103-0 Twister Spruhkammer
810-88048-0 Consumables set ICP-MS standard for PlasmaQuant MS all models
418-88027-0 Pump tubing orange/green (0.015 in. ID), flared ends
418-10-406-227 Cyclonic spray chamber PQMS ,20 mL, Borosilicate glass

Downloads

Brochure High-performance LC ICP mit PlasmaQuant-MS und PQ LC (DE)
Brochure High-performance LC ICP MS on PlasmaQuant MS and PQ LC (EN)
Brochure PlasmaQuant MS series (EN)
Brochure PlasmaQuant MS series (RU)
Broschüe PlasmaQuant MS series (DE)
EU Declaration of Conformity PlasmaQuant MS Serie
Flyer Analyse élémentaire des déchets (FR)
Flyer Calibration Standard Offering for TOC, AAS, and ICP Devices (EN)
Flyer Kalibrierstandards für TOC-, AAS- und ICP-Geräte (DE)
Flyer PlasmaQuant MS in Contact Lab Analysis (EN)
Flyer PlasmaQuant MS in Environmental Monitoring (EN)
Flyer PlasmaQuant MS in Food and Agricultural Analysis (EN)
Flyer PlasmaQuant MS in Geology and Mining and Metals Industry (EN)
Flyer PlasmaQuant MS in in Organic Solvents and Petrochemical Analysis (EN)
Flyer PlasmaQuant MS in the Pharmaceutical Industry (EN)
Product Guide Chemical Analysis (EN)
Produktkatalog Chemische Analyse (DE)
Technical Data PlasmaQuant MS (EN)
TechNote PlasmaQuant MS Accessories (EN)
TechNote PlasmaQuant MS Eco Plasma (EN)
TechNote PlasmaQuant MS iCRC (EN)
TechNote PlasmaQuant MS Lab Preparation (EN)
TechNote PlasmaQuant MS Laborvorbereitung (DE)
TechNote PlasmaQuant MS ReflexION (EN)

Contact us We are happy to help you and will contact you as quickly as possible.