AOX, AOF and EOF Sample Preparation Series Take the Fast Lane to Success
- AOX enrichment acc. column method, e.g., ISO 9562
- AOF enrichment acc. column method, DIN 38409-59, EPA 1621
- Samples for EOF determination (water)
- Robust hardware – minimum maintenance and downtime
- Flexibility – easy adaptation to AOX, AOF (CIC) and EOF analysis using HR-CS-MAS (contrAA 800 series) for PFAS as a non-targeted sum parameter
- Easy operation
Our systems help to minimize unproductive downtime and preparation effort, while increasing your throughput of AOX, AOF and EOF samples and thereby remaining flexible and cost-effective.
The smart way of AOX, AOF and EOF sample preparation
Sample preparation is the bottleneck in AOX, AOF and EOF analysis. There are numerous obstacles that can distort analysis results. Standard-compliant sample preparation is therefore essential to ensure reliable analyses and a time-saving, easy-to-use workflow. Get to know our harmonized concepts of sample preparation and analysis and benefit from the efficiency and versatility our systems offer.
- Optimum adaptation to your application and throughput demands – semi-automated up to fully-automated workflows
- Unique efficiency by harmonized sample preparation and combustion systems – allows for up to 112 samples per day
- Maximized efficiency – preparation of up to 6 samples simultaneously
- Standard-compliant operation
- Application versatility – EOF, AOX-SPE, AOF, AOX batch and column method, one, two and three-column methods
- Wide portfolio of AOX and AOF columns and activated carbon – prefilled disposable columns and re-usable quartz columns
- Comfortable, easy operation by integrated control – no extra PC required
Brochures
Title | Language | Info |
---|---|---|
Flyer APU sim (DE) | de | PDF, 299 KB |
Flyer APU sim (EN) | en | PDF, 294 KB |
Flyer AOX-Probenvorbereitung - APU-Serie (DE) | de | PDF, 400 KB |
Flyer AOX Sample Preparation - APU Systems (EN) | en | PDF, 325 KB |
Flyer Solid Waste Analysis - Halogen Determination in Waste and Recycling (EN) | en | PDF, 1 MB |
Flyer AOX-Probenvorbereitung nach Säulenmethode (DE) | de | PDF, 554 KB |
Flyer AOX Sample Preparation - Column vs. Batch Method (EN) | en | PDF, 541 KB |
Flyer AOX-Probenvorbereitung - APU-Serie (DE) | de | PDF, 400 KB |
Flyer APU 28 connect (EN) | en | PDF, 617 KB |
Analyse des déchets solides - Détermination des halogènes (FR) | fr | PDF, 1 MB |
Flyer Chemical Recycling of Plastics: Analytical Solutions for Crucial Quality Gates (EN) | en | PDF, 301 KB |
AOX, AOF and EOF analysis made profitable
Reach a new benchmark in AOX, AOF and EOF analysis efficiency! A wide portfolio of matrix-, application-, and throughput-optimized sample preparation systems allow for maximum throughput at minimum operation effort. Benefit from reduced idle times, robust hardware, and minimum maintenance requirements.
APU 28 series – Smart AOX and AOF sample preparation according to column method
APU 28 connect combines usability and speed in AOX and AOF sample preparation. The touch display offers intuitive operation with minimal effort and reduced programming time for any skill level. Parallel sample enrichment allows you to reduce the preparation time in your lab significantly. The highly durable components guarantee a long service life and enable 24/7 operation.
- Fast: Automatic enrichment of up to 28 samples
- Smart: Intuitive operation via touch display
- Flexible: Wide range of applications – SPE-AOX, AOX and AOF column method
The SPE option is ideal for saline samples. It enables AOX, AOF and SPE sample preparation with one device, significantly simplifying your routine analysis. All APU 28 connect systems can be used with AOX/AOF adsorption columns of other manufacturers. A flexible tray and optimized column holders enable fast and easy processing.
APU sim – Ideal for small sample series
APU sim offers the simultaneous and fast enrichment of up to six AOX or AOF samples using the column method, or semi-automated processing of SPE samples, or preparation of up to 6 water samples for EOF analysis. Designed with three enrichment channels, each channel can be operated and started individually. Sample volume, wash volume, and flow rate are adjusted individually and variably. The system stands out with excellentparticle handling thanks to the large diameters of the hoses and the absence of conventional valve technology.
- Wide application range – AOX and AOF column method, SPE-AOX or EOF
- Cost-effective solution for small sample series
- High throughput speed – up to 6 samples prepared simultaneously
- Suitable for particle-containing and saline samples
- Column flexibility – utilization of versatile AOX and AOF column brands and sizes
AFU 3 – The versatile all-rounder
The system allows for semi-automated sample preparation of up to three samples according to batch and column method. It’s an effective alternative to classical membrane filtration as using expensive polycarbonate filters is not necessary. Filtration is done directly into a frit container. The system can be extended easily for semi-automated preparation of up to three samples according to column method.
- AOX sample preparation according to batch and column method
- Semi-automated enrichment of up to three samples simultaneously
- Attractive alternative to classic membrane filtration (batch)
- Easy operation, fast processing without sample loss – pressure-supported filtration (batch)
- High operational safety – pressure proof sample vessels and protective front cover
Products
AFU 3 Automatic Filtration Unit
The allrounder – semi-automated AOX sample preparation according batch or column method. Cost-effective alternative to classic membrane filtration.
Order number: 450-126.971
APU 28 connect S
AOX and AOF sample preparation – take the fast lane to success
Order number: 450-126.984
APU 28 connect SPE
AOX and AOF sample preparation – robust and versatile
Order number: 450-126.985
APU sim Automatic Preparation Unit
The clever one - ideal solution for small AOX, AOF and EOF sample series
Order number: 450-900.300
Applications
Applications
-
Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)
-
Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)
-
Bestimmung des Parameters AOX in Klärschlamm mittels Schüttelmethode gemäß EN 16166 (DE)
-
Determination of AOX in Sewage Sludge Samples by Batch Method According to EN 16166 (EN)
-
Probenvorbereitung für die Bestimmung des AOF in Wässern nach E DIN 38409-59 (DE)
-
Sample Preparation for the Determination of AOF in Water Samples According to E DIN 38409-59 (EN)
-
Bestimmung des AOX in Grund-, Roh- und Trinkwasser sowie in Oberflächengewässern gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Raw, Drinking, and Groundwater, as well as in Surface Water in Accordance with ISO 9562 (EN)
-
Applikationschrift Bestimmung des AOX in Abwasserproben nach Schüttelmethode gemäß DIN EN ISO 9562 (DE)
-
Application Note Determination of AOX in Wastewater Samples by Batch Method in Accordance with EN ISO 9562 (EN)
Applications
-
Determination of Adsorbable Organic Halogens in Highly Saline Water Samples after Solid Phase Extraction (EN)
-
Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)
-
Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)
-
Bestimmung des Parameters AOX in Klärschlamm mittels Schüttelmethode gemäß EN 16166 (DE)
-
Determination of AOX in Sewage Sludge Samples by Batch Method According to EN 16166 (EN)
-
Probenvorbereitung für die Bestimmung des AOF in Wässern nach E DIN 38409-59 (DE)
-
Sample Preparation for the Determination of AOF in Water Samples According to E DIN 38409-59 (EN)
-
Bestimmung des AOX in Grund-, Roh- und Trinkwasser sowie in Oberflächengewässern gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Raw, Drinking, and Groundwater, as well as in Surface Water in Accordance with ISO 9562 (EN)
-
Applikationschrift Bestimmung des AOX in Abwasserproben nach Schüttelmethode gemäß DIN EN ISO 9562 (DE)
-
Application Note Determination of AOX in Wastewater Samples by Batch Method in Accordance with EN ISO 9562 (EN)
Applications
-
Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)
-
Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)
-
Bestimmung des Parameters AOX in Klärschlamm mittels Schüttelmethode gemäß EN 16166 (DE)
-
Determination of AOX in Sewage Sludge Samples by Batch Method According to EN 16166 (EN)
-
Probenvorbereitung für die Bestimmung des AOF in Wässern nach E DIN 38409-59 (DE)
-
Sample Preparation for the Determination of AOF in Water Samples According to E DIN 38409-59 (EN)
-
Bestimmung des AOX in Grund-, Roh- und Trinkwasser sowie in Oberflächengewässern gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Raw, Drinking, and Groundwater, as well as in Surface Water in Accordance with ISO 9562 (EN)
Applications
-
Bestimmung von adsorbierbaren organisch gebundenen Halogenen in stark salzhaltigen Wasserproben nach Festphasenextraktion (DE)
-
Bestimmung des AOX in Abwasserproben mittels Säulenmethode gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Wastewater Samples by Column Method According to DIN EN ISO 9562 (EN)
-
Bestimmung des Parameters AOX in Klärschlamm mittels Schüttelmethode gemäß EN 16166 (DE)
-
Determination of AOX in Sewage Sludge Samples by Batch Method According to EN 16166 (EN)
-
Probenvorbereitung für die Bestimmung des AOF in Wässern nach E DIN 38409-59 (DE)
-
Sample Preparation for the Determination of AOF in Water Samples According to E DIN 38409-59 (EN)
-
Bestimmung des AOX in Grund-, Roh- und Trinkwasser sowie in Oberflächengewässern gemäß DIN EN ISO 9562 (DE)
-
Determination of AOX in Raw, Drinking, and Groundwater, as well as in Surface Water in Accordance with ISO 9562 (EN)
-
Applikationschrift Bestimmung des AOX in Abwasserproben nach Schüttelmethode gemäß DIN EN ISO 9562 (DE)
-
Application Note Determination of AOX in Wastewater Samples by Batch Method in Accordance with EN ISO 9562 (EN)
Technical Data
Dimension (width x depth x height) |
|
---|---|
AFU 3 Automatic Filtration Unit |
300 mm x 300 mm x 800 mm |
APU 28 connect S |
700 mm x 550 mm x 650 mm |
APU 28 connect SPE |
700 mm x 550 mm x 650 mm |
APU sim Automatic Preparation Unit |
450 mm x 205 mm x 600 mm |
Standards
- APHA SM 5320 B
- ASTM D4744
- DIN 38409-22
- DIN 38409-59
- DIN 38414-18
- DIN EN 1485
- DIN EN 16166
- DIN EN ISO 9562
- EPA 1621
- EPA 1650C
- EPA 450.1
- EPA 9020B
Order Information
Order number |
Description |
---|---|
450-126.971 | AFU 3 Automatic Filtration Unit |
450-126.984 | APU 28 connect S |
450-126.985 | APU 28 connect SPE |
450-900.300 | APU sim Automatic Preparation Unit |
Accessories
APU sim Kit AOF | 450-900.302 |
APU sim Kit AOX | 450-900.301 |
APU sim Kit EOF | 450-900.303 |
Kit batch method for AFU 3 | 450-126.972 |
Rack for AJ columns for APU 28 series | 450-889.598 |
Kit column method for AFU 3 | 450-126.973 |
Rack column flexibility for APU 28 series | 450-889.597 |
Duplex column holder for quartz container Type 1 | 402-880.631 |
Duplex column holder for quartz container Type 2 | 402-880.632 |
Duplex column holder for APU series | 402-889.615 |
Filling device for activated carbon (20 mg) | 402-880.212 |
Filling device for activated carbon (50 mg) | 402-880.114 |
Triplex column holder for 3 quartz container | 402-889.616 |
Rack for filling quartz containers 18 x 6 and 18 x 8 mm | 402-880.019 |
Software
The APU series systems are operated with inclusive control unit and easy to understand software.
The operation software is included. The user interface is easy understandable, and intuitive, independant of operators experience level.
Product | Required | Included |
---|---|---|
APU 28 connect S (450-126.984) | ||
APU 28 connect SPE (450-126.985) | ||
APU sim Automatic Preparation Unit (450-900.300) |
Consumables
402-810.004 | Activated carbon for AOX column method |
402-825.126 | Aluminum foil rondes , set |
402-880.610 | Set of 100 disposable tubes for AOX 18 x 6 mm, filled |
402-889.629 | Aspiration tube assembled |
402-889.628 | Aspiration tube for APU 28 |
402-950.033 | Canister for nitrate rinse solution |
402-007.988 | FAST connector straight |
402-950.035 | Hose kit 28/1 and 28 connect |
402-950.036 | Hose kit APU 28/1 and APU 28 connect |
11-815.840 | O-ring for Luer-adapter column holder |
402-889.698 | Sample vessel without screw thread for APU 28 |
402-889.631 | Sealing cone, complete |
402-889.632 | Set O-rings for sealing cone APU 28 |
402-950.014 | Tubing kit for APU 28 systems |
402-889.802 | Waste tube APU 28 |
402-890.999 | Set O-rings Duplex column holder type 1 |
402-890.998 | Set O-rings Duplex column holder type 2 |
402-880.621 | Set of 100 disposable tubes for AOX, 40 x 9 mm, filled |
402-880.607 | Set of 100 disposable tubes for AOF 18 x 6 mm, filled |
402-880.620 | Set of 100 disposable tubes for AOF, 40 x 9 mm, filled |
402-880.615 | Set of 300 disposable tubes for AOX 18 x 6 mm, filled |
402-810.025 | Activated carbon for AOX batch method |
402-889.644 | Bottom part of column holder for AFU 3 |
402-890.707 | Disposable syringe APU sim |
402-889.642 | Flat gasket for AFU 3 sample preparation |
402-890.711 | Hose set APU sim |
402-890.710 | Luer connection APU sim |
402-880.657 | O-ring for AFU 3 and DF3U |
402-890.712 | O-ring for APU sim |
402-880.013 | Quartz container, 18 x 8 mm, thick-walled |
402-889.645 | Quartz container, thin-walled, 18 x 8 mm |
402-880.651 | Sample vessel with column head for DF3U |
402-889.640 | Sample vessel with column head for AFU 3 |
402-880.609 | Set of 100 disposable tubes 18 x 8 mm, filled |
450-VM-AOXSH | Set of consumables for batch method |
402-890.728 | Set of disposable syringes APU sim |
402-890.726 | Set replacement tube elements for APU sim |
402-890.709 | Waste hose silicone 8 x 11 mm |
Downloads
The newsletter of Analytik Jena frequently keeps you posted about:
- News
- Trends and developments
- Events